■News

The difference between low-temperature ball valve and ordinary ball valve

Publication date:2026-10-31 09:44:46 Click:

The working media of low-temperature ball valves are mostly flammable, explosive, and highly permeable substances, with a minimum operating temperature reaching -269°C and a maximum service pressure up to 10 MPa, making the operating conditions extremely demanding. Therefore, the design, manufacturing, and inspection of low-temperature valves differ significantly from those of ambient-temperature valves.

 

Low-temperature valves refer to valves capable of operating under cryogenic conditions, typically defined as valves with operating temperatures below -40°C. Low-temperature ball valves are essential equipment in industries such as petrochemicals, air separation, and natural gas, and their quality directly determines whether production can be conducted safely, economically, and continuously. With advances in modern technology, the applications of low-temperature valves continue to expand, leading to increasing demand.

 

From a materials perspective, for example, VITON's low-temperature ball valves from the United States offer over ten types of materials, including CF8, LCB, LF1, and F304, suitable for various temperatures and media. Relevant standards have been established, specifying not only dimensional and surface quality requirements for castings and forgings but also strict technical specifications regarding chemical composition, heat treatment, mechanical properties, physical properties, welding repairs, post-weld heat treatment, non-destructive testing, intergranular corrosion tests (for austenitic steels), and impact tests (for low-temperature valves).

 

According to the manufacturing standards and requirements of VITON's low-temperature ball valves, these valves possess distinct characteristics compared to conventional ball valves:

 

1. General Design Requirements for Low-Temperature Valves

 

(1) The valve and its assembly must be capable of long-term operation under cryogenic media and surrounding environmental temperatures (typically 10 years or 3,500 to 5,000 cycles);

 

(2) The ball valve should not act as a significant heat source relative to the cryogenic medium, as heat inflow reduces thermal efficiency; excessive heat input may cause vaporization of the internal cryogenic medium, resulting in abnormal pressure rise and potential hazards;

 

(3) The cryogenic medium should not adversely affect the operability of the handwheel or the sealing performance of the packing;

 

(4) The structure of components in direct contact with the cryogenic medium must comply with relevant explosion-proof and fire-resistant requirements;

 

(5) Components operating at low temperatures cannot be lubricated; therefore, measures must be taken to prevent friction surfaces from being scratched.

 

These requirements must be consistently applied throughout the entire design process of low-temperature valves. Additionally, it should be noted that these are specific requirements unique to low-temperature valves, while general valve design standards must also be observed simultaneously.

 

2. Cooling Performance of Low-Temperature Valves

 

Cooling performance refers to the ability of a low-temperature ball valve to cool down from ambient temperature to its operating temperature. This performance can be evaluated by the energy consumed during this process—specifically, the amount of heat Q2 transferred from the valve to the cryogenic medium. For periodically operated low-temperature valves, cooling performance is critically important. However, relying solely on Q2 is insufficient; alternative performance indicators should be considered.

 

3.1 Material Selection for Valve Body, Bonnet, Seat, and Disc

 

Ferritic stainless steel may be used when the temperature is above -100°C, while austenitic stainless steel is preferred for temperatures below -100°C. For low-pressure and small-diameter valves, copper alloys or aluminum alloys may be selected.

 

3.2 Stem Material Selection

 

Stems should be made of austenitic acid-resistant stainless steel and subjected to appropriate heat treatment to enhance tensile strength. They must also be coated with hard chrome (coating thickness 0.04–0.06 mm) or undergo nitriding treatment to increase surface hardness.

 

3.3 Fastener Material Selection

 

 

 

 

 

When the temperature is above -100°C, bolt materials should be alloy steels such as Ni or Cr-Mo, which must undergo appropriate heat treatment to prevent thread galling. When the temperature is below -100°C, austenitic stainless steel may be used for bolts. Nut materials are generally made of Mo steel or Ni steel, and the threaded surfaces should be coated with molybdenum disulfide.

 

3.4 Gasket Material Selection

 

For service temperatures above -196°C and maximum allowable pressure up to 3 MPa at low temperatures, asbestos rubber sheets made from long-fiber asbestos can be used. For service temperatures above -196°C and maximum allowable pressure up to 5 MPa at low temperatures, spiral-wound gaskets with stainless steel wrapping and asbestos, stainless steel wrapping and PTFE, or stainless steel wrapping and expanded graphite can be employed.

 

It should be emphasized that all low-temperature material components must undergo deep cryogenic treatment prior to final machining to minimize shrinkage and deformation in low-temperature valves under cold operating conditions.

 

4. Low-Temperature Valve Structural Design

 

The structure of low-temperature valves differs significantly from that of standard valves. In designing low-temperature valves, in addition to general valve structural requirements, several key issues must be addressed:

 

(1) After a low-temperature valve closes, the residual low-temperature medium inside the valve body rapidly vaporizes due to temperature rise, causing abnormal internal pressure increase;  

(2) The adverse effects of low temperature on packing seal performance;  

(3) The harmful impact of cold-induced deformation on valve components;  

(4) Explosion-proof requirements for components exposed to low-temperature media.

 

It should also be noted that low-temperature ball valves operate not only under low-temperature media but also under ambient environmental conditions—typically around 20°C. This factor must be considered, especially when designing sealing elements for opening and closing operations.

 

Based on actual field requirements, the following basic design criteria are proposed for low-temperature valves:

 

(1) The valve body must be capable of fully withstanding thermal expansion and contraction caused by temperature changes, and the seat area structure must not suffer permanent deformation due to temperature fluctuations;

 

(2) Use a long-neck bonnet structure to protect the packing gland;

 

(3) Employ disc designs that maintain reliable sealing regardless of temperature variation—for example, elastic gate plates or open-type gate plates for gate valves, and conical discs for globe valves;

 

(4) Incorporate upper-sealing structures;

 

(5) Use valve seat and disc sealing faces with hardfacing welds of tungsten carbide-cobalt alloy;

 

(6) Include pressure-relief holes to prevent abnormal pressure buildup. The location of these relief holes depends on the valve structure and may be placed either on the valve body or on the gate plate.

 

4.1 Design of Low-Temperature Ball Valve Bodies

 

The valve body is the primary pressure-bearing component and must have sufficient strength to ensure normal valve operation. Under low-temperature conditions, the valve body experiences significant low-temperature stresses, as well as additional stresses from thermal expansion and contraction. To prevent deformation of the sealing pair, the valve body must possess adequate rigidity. Additionally, to avoid damage caused by stress concentration at low temperatures, sharp corners and grooves should be avoided in the valve body design.

 

4.2 Design of Long-Neck Bonnets for Low-Temperature Valves

 

Low-temperature valves require a long-neck bonnet design, whose purpose is to reduce heat transfer into the valve assembly from the external environment; maintain the temperature of the packing gland above 0°C so that the packing functions properly; and prevent frost or freezing of the stem and upper parts of the bonnet due to excessive cooling in the packing area.

 

 

 

 

 

The design of the long neck bonnet primarily involves determining the neck length L, which refers to the distance from the bottom of the packing gland to the upper surface of the sealing seat (as shown in Figure 1). This dimension is related to factors such as the material's thermal conductivity, heat transfer area, surface heat dissipation coefficient, and heat dissipation area. The calculation is complex and typically determined experimentally. Under normal circumstances, values can be selected according to Table 2.

 

In industrial applications, the neck dimension may be appropriately extended based on actual site conditions, such as insulation requirements, operational space, and installation location.

 

4.3 Design of Pressure Relief Components

 

Abnormal pressure rise generally occurs only in low-temperature gate valves. After the gate valve disc closes, the residual low-temperature medium inside the valve body absorbs a large amount of heat from the surrounding environment, rapidly vaporizing and generating extremely high internal pressure. This abnormal pressure increase poses significant risks: it may tightly press the disc against the seat, causing the disc to jam and preventing proper valve operation; it could also damage the packing and flange gaskets, or even lead to valve body rupture. Therefore, measures must be taken to prevent this phenomenon.

 

Common solutions include designing pressure relief holes and installing bypass systems. For small-diameter valves (DN ≤ 300 mm), a pressure relief hole can be directly designed near the high-pressure side (i.e., inlet end) of the gate disc. For larger valves, a bypass system is required. Low-temperature valves equipped with pressure relief holes or bypass systems must clearly indicate the direction of media flow.

 

4.4 Design of Upper Seal Device

 

An upper seal device is a mechanism that prevents working medium leakage toward the packing gland when the valve is fully open.

 

The upper seal device serves two purposes. First, it reduces damage to the packing caused by the working medium. Industrial valves remain open for most of their operating time; without an upper seal, the medium pressure acts directly on the packing, leading to prolonged stress and premature aging. Second, when leakage occurs at the packing area, opening the valve fully activates the upper seal device, enabling packing replacement under pressure. Therefore, both gate valves and globe valves are required to have an upper seal device.

 

The upper sealing surface can be produced by welding and drilling hard alloy (such as chromium-tungsten carbide) onto the bonnet, followed by precision machining and grinding. Alternatively, it can be ground directly onto a dedicated upper sealing seat. For bonnets made of austenitic stainless steel, the upper seal surface can be machined directly into the bonnet.

 

In summary, during the design of low-temperature valves, various effects of low temperature on valve performance must be comprehensively considered. Appropriate structural designs should be adopted to minimize adverse impacts on normal valve operation.

 

5 Inspection of Low-Temperature Valves

 

Low-temperature valves must undergo not only ambient temperature testing but also low-temperature testing.

 

Ambient temperature tests mainly include shell hydrostatic strength test, water and air tightness tests, upper seal test, and opening/closing and torque tests.

 

The primary purpose of low-temperature testing is to evaluate the valve’s operational and sealing performance under low-temperature conditions. Operational performance requires smooth opening and closing, with no scoring or seizing of moving parts or sealing surfaces. Sealing performance requires that the leakage rate at the sealing surface remains below the allowable limit.

 

In summary, low-temperature ball valves require stainless steel materials treated with deep cryogenic processing, must feature extended stem design, and must be capable of handling media such as LNG, liquid nitrogen, liquid oxygen, and liquefied natural gas at temperatures as low as -196°C.